SCHUCK builder's package MHP for sealing pipes (water / electricity) from Ø19mm up to Ø40.5mm in the slab

House entry for buildings without basement.

House entry for buildings without basement.

For buildings without basements – house introductions for everyone.

The Schuck builder's package provides everything you need for standard-compliant and professional installation of a house entry into the basement wall. The builder's package for installation in the wall includes all the necessary accessories and materials for installing a 1-section house entry.

Standard-compliant solutions for house introductions with the Schuck builder package:

BHP19_40_5.png

1. Wall Installation Ø19-40.5mm

Installation of a 1-supply house entry with a diameter of 19-40.5mm in the basement wall.

Read on..

BHP39_63_5.png

2. Wall Installation Ø39-63,5mm

Installation of a 1-supply house entry with a diameter of 39-63.5mm in the basement wall.

Read More

House entry for buildings without basement.

3. Installation in the Slab

The builder's package is also available as a variant for installation in the floor slab with flexible pipe (RG66/60).

More Info

iStock-1201806395  - Shopping Cart.jpg

NEW:

  • SCHUCK builder's packages are
  • available in the E.DIS Netz GmbH online shop.

Visit Shop

Assembly Instructions for SCHUCK Builder's package for slab installation

One-size Ø19-40.5mm. For buildings without a basement - whether new or existing - with flexible pipe using SCHUCK MHP-FLEX house entry.

1-section house introduction for buildings without a basement

1-section house introduction for buildings without a basement

REQUIREMENTS

This 1-section house introduction for buildings without a basement can be installed in both new buildings and existing ones. The standard installation is described below. Structural conditions may require a different approach. The installation steps described must be implemented accordingly. Examples are listed at the end of this guide. The installation position of the house entry (1) must be chosen so that the rigid part (1a, shown in black) can be cast in the area of ​​the base plate (10), and the flexible part (1b) extends to the front of the building (11). The opening in the base plate must not exceed a diameter of 210 mm or an edge length of 190 mm for a square opening. A round opening with a diameter of 150mm is recommended. Distance from wall to center of opening: 120mm.

SCHUCK builder's package for installation in the floor slab.

SCHUCK builder's package for installation in the floor slab.

Scope of delivery of builder’s package for slab installation

  1. House entry MHP-FLEX (RG66/60 or RG95/90).
  2. Wall bracket - Mounting fixture, to hold everything in place.
  3. Five bags of 2 kg grout Schuck Beto-Fix Plus with measuring cup.
  4. Filling funnel.
  5. Drain Stop (foam).

INSTALLATION STEP BY STEP

The wall bracket (2) is used to secure the house entry during installtion.

The wall bracket (2) is used to secure the house entry during installtion.

1. MOUNTING THE WALL BRACKET

The assembly assistant device or wall bracket (2) is used to fix the house entry (1) so that it does not move during casting and curing. The wall bracket (2) is placed so that it can hold the house entry (1) in the upper area and the house entry (1) only protrudes minimally over the finished floor (12). Attach the wall bracket (2) a maximum of 200mm above the unfinished floor (13) so that there is still at least 150mm of the rigid part of the house entry (1a) in the floor plate (10).

2. INSERTING THE HOUSE ENTRY

Push the house entry (1) through the slap opening from the house and fix it to the wall bracket (2) in the upper area.

Watch bending radius and installation depth!

Watch bending radius and installation depth!

3. ALIGN FLEXIBLE PART

a. Bending radius (R)

The flexible part (1b) must be guided in such a way that the smallest permissible bending radius (Rmin) of 500mm is not exceeded. Recommendation: R = 1000mm The smallest bending radius (Rmin) of the media line to be inserted later must be taken into account and, if necessary, requested from the energy supplier.

b. Pipe cover (RD)

The end of the flexible part must extend to the edge of the building and must not end below the building (11)! The required laying depth (pipe cover RD) must be maintained below the top edge of the ground level (GOK). Recommendation: RD = 1000mm

Fill cavities with sand or similar aggerates.

Fill cavities with sand or similar aggerates.

4. SAND BACKFILLING

In the area under the base plate (10), the existing cavity (14) can be filled with suitable material (14). Suitable material must be free of sharp objects (e.g. stones) that can damage the house entry (1)! The cavity (14) is filled to a maximum of the lower edge of the base plate (10) and is intended to prevent later settlement of the surrounding material.

Prepare for next step: grouting.

Prepare for next step: grouting.

5. INSERT THE DRAIN STOP

The drain stop (5) is made of foam and is inserted into the annular space between the house entry (1) and the base plate (10) in such a way that the Schuck Beto-Fix Plus is prevented from flowing off during the subsequent casting. To do this, the drain stop (5) is installed in the area of ​​the lower edge of the base plate (10) in such a way that it closes the annular space all the way down and is installed so low that there is a minimum grouting length (L) of 150mm all around between the house entry (1) and the base plate (10) is possible.

When mixing Beto-Fix, it is necessary to adhere to the quantity instructions.

When mixing Beto-Fix, it is necessary to adhere to the quantity instructions.

8. PREPARE GROUTING PART I

Info: 5 bags of Schuck Beto-Fix Plus make approx. 5 litres of ready mix.

Pour 5 measuring cups of 300 ml water into the bucket (total 1.5 litres, keep to the exact amount of water!) Add 5 bags of Schuck Beto-Fix Plus (3).

(If more material is needed due to particularly thick walls or large wall openings, use more material, available at www.schuck-leerrohrsystem.de).

It is also important to observe the time intervals when mixing.

It is also important to observe the time intervals when mixing.

9. PREPARE GROUTING PART II

Mix well by hand with a trowel or with a slowly rotating mixer for a maximum of one minute, avoiding the formation of lumps. Allow Schuck Beto-Fix Plus to rest for approx. 30 seconds after mixing. Do not stir again afterwards.

Pour Beto-Fix Plus quickly.

Pour Beto-Fix Plus quickly.

10. GROUTING PROCESS

Quickly pour Schuck Beto-Fix Plus (15) into the annular space between the house entry (1) and the base plate (10). For this purpose, it can be helpful to create a temporary channel in the form of a folded cardboard box and allow the material to flow into the annular gap. Pour in Schuck Beto-Fix Plus (15) at least until the minimum casting length (L) of 150mm is reached. Depending on the temperature and weather, Schuck Beto-Fix Plus (15) begins to harden after 5 to 10 minutes and is fully hardened after approx. 20 to 60 minutes. The house entry (1) is now installed correctly!

Further information about pipe installation behind the protective cap.

Further information about pipe installation behind the protective cap.

13. INSTALLATION OF THE PIPE

Install and seal the cable in accordance with the "Installation Instructions for Schuck Modular House Entry MHP and MHP-FLEX". These can be found under the protective cap of the MHP on the inside of the building. The cable can be installed later and is usually carried out by the energy supplier.

ALTERNATIVE INSTALLATIONS

Exceptions when installing in the base plate.

Exceptions when installing in the base plate.

Example ( compare step 4.)

Examples of different procedures due to structural conditions

Examples for new buildings:

1. The house entry is set up before the floor slab is created, aligned with the batter board and temporarily fixed. Auxiliary structures made of wood or steel reinforcement of the base plate can be useful for this. The house entry is then cast into the concrete when the floor slab is created. The concrete must be sufficiently compacted all around in the area of ​​the house entrance!

2. The house entry is installed in a pre-laid empty pipe. Common empty pipes are KG pipes or cable protection pipes. The bending radius (R) must be taken into account when creating the empty pipe. If an approved casing pipe is not used in the area through the base plate (not permitted: KG pipe, KG2000 pipe, HT pipe, cable protection pipe, etc. Approved casing pipe available at www.schuck-leerrohrsystem.de), this piece of pipe must be used before installing the pipe House entry (1) in this area must be removed. The casting directly between the house entry (1) and the base plate (10) over the minimum casting length of 150mm must be ensured and adhered to! Further installation is carried out as described in these instructions.

Examples for existing buildings:

3. On the outer wall, a core hole is drilled vertically downwards in the building through the floor plate. Excavation is carried out in front of the building and access to the core drilling is uncovered, through which the house entry can be led. Installation is then carried out as described in these instructions.

4. On an outside wall, an approximately 45° sloping hole is drilled through the floor plate towards the outside of the building. The position and angle must be chosen so that the core drilling in front of the building achieves sufficient pipe coverage. Further installation is carried out as described in these instructions.

GENERAL

Valid regulations, standards and specifications must be observed, even if they are not explicitly mentioned in these instructions!

SCHUCK House Entries - Simple. Secure. Sealed.

SCHUCK House Entries - Simple. Secure. Sealed.

SCHUCK Builder's Package "House Entry MHP"

SCHUCK Builder's Package "House Entry MHP"

Would you like to install it in the basement wall? - SCHUCK builder package MHP

Two installation sizes for the wall installation builder package

Available sizes Ø19-40.5mm and Ø39-63.5mm.

SEE INSTALLATION INSTRUCTIONS

DOWNLOAD & BONUS MATERIAL:

Click on the desired document to download the installation instructions.

BUY HOUSE ENTRY ONLINE:

iStock-1201806395  - Shopping Cart.jpg
  • SCHUCK builder's packages are
  • available in the E.DIS Netz GmbH online shop.

Visit Shop